AWS::IoTWireless::DeviceProfile LoRaWANDeviceProfile - Amazon CloudFormation
Services or capabilities described in Amazon Web Services documentation might vary by Region. To see the differences applicable to the China Regions, see Getting Started with Amazon Web Services in China (PDF).

AWS::IoTWireless::DeviceProfile LoRaWANDeviceProfile

LoRaWAN device profile object.

Syntax

To declare this entity in your Amazon CloudFormation template, use the following syntax:

JSON

{ "ClassBTimeout" : Integer, "ClassCTimeout" : Integer, "FactoryPresetFreqsList" : [ Integer, ... ], "MacVersion" : String, "MaxDutyCycle" : Integer, "MaxEirp" : Integer, "PingSlotDr" : Integer, "PingSlotFreq" : Integer, "PingSlotPeriod" : Integer, "RegParamsRevision" : String, "RfRegion" : String, "RxDataRate2" : Integer, "RxDelay1" : Integer, "RxDrOffset1" : Integer, "RxFreq2" : Integer, "Supports32BitFCnt" : Boolean, "SupportsClassB" : Boolean, "SupportsClassC" : Boolean, "SupportsJoin" : Boolean }

YAML

ClassBTimeout: Integer ClassCTimeout: Integer FactoryPresetFreqsList: - Integer MacVersion: String MaxDutyCycle: Integer MaxEirp: Integer PingSlotDr: Integer PingSlotFreq: Integer PingSlotPeriod: Integer RegParamsRevision: String RfRegion: String RxDataRate2: Integer RxDelay1: Integer RxDrOffset1: Integer RxFreq2: Integer Supports32BitFCnt: Boolean SupportsClassB: Boolean SupportsClassC: Boolean SupportsJoin: Boolean

Properties

ClassBTimeout

The ClassBTimeout value.

Required: No

Type: Integer

Minimum: 0

Maximum: 1000

Update requires: No interruption

ClassCTimeout

The ClassCTimeout value.

Required: No

Type: Integer

Minimum: 0

Maximum: 1000

Update requires: No interruption

FactoryPresetFreqsList

The list of values that make up the FactoryPresetFreqs value. Valid range of values include a minimum value of 1000000 and a maximum value of 16700000.

Required: No

Type: Array of Integer

Maximum: 20

Update requires: No interruption

MacVersion

The MAC version (such as OTAA 1.1 or OTAA 1.0.3) to use with this device profile.

Required: No

Type: String

Maximum: 64

Update requires: No interruption

MaxDutyCycle

The MaxDutyCycle value.

Required: No

Type: Integer

Minimum: 0

Maximum: 100

Update requires: No interruption

MaxEirp

The MaxEIRP value.

Required: No

Type: Integer

Minimum: 0

Maximum: 15

Update requires: No interruption

PingSlotDr

The PingSlotDR value.

Required: No

Type: Integer

Minimum: 0

Maximum: 15

Update requires: No interruption

PingSlotFreq

The PingSlotFreq value.

Required: No

Type: Integer

Minimum: 1000000

Maximum: 16700000

Update requires: No interruption

PingSlotPeriod

The PingSlotPeriod value.

Required: No

Type: Integer

Minimum: 128

Maximum: 4096

Update requires: No interruption

RegParamsRevision

The version of regional parameters.

Required: No

Type: String

Maximum: 64

Update requires: No interruption

RfRegion

The frequency band (RFRegion) value.

Required: No

Type: String

Maximum: 64

Update requires: No interruption

RxDataRate2

The RXDataRate2 value.

Required: No

Type: Integer

Minimum: 0

Maximum: 15

Update requires: No interruption

RxDelay1

The RXDelay1 value.

Required: No

Type: Integer

Minimum: 0

Maximum: 15

Update requires: No interruption

RxDrOffset1

The RXDROffset1 value.

Required: No

Type: Integer

Minimum: 0

Maximum: 7

Update requires: No interruption

RxFreq2

The RXFreq2 value.

Required: No

Type: Integer

Minimum: 1000000

Maximum: 16700000

Update requires: No interruption

Supports32BitFCnt

The Supports32BitFCnt value.

Required: No

Type: Boolean

Update requires: No interruption

SupportsClassB

The SupportsClassB value.

Required: No

Type: Boolean

Update requires: No interruption

SupportsClassC

The SupportsClassC value.

Required: No

Type: Boolean

Update requires: No interruption

SupportsJoin

The SupportsJoin value.

Required: No

Type: Boolean

Update requires: No interruption