AWS::SageMaker::MonitoringSchedule StoppingCondition
Specifies a limit to how long a job can run. When the job reaches the time limit, SageMaker ends the job. Use this API to cap costs.
To stop a training job, SageMaker sends the algorithm the SIGTERM
signal,
which delays job termination for 120 seconds. Algorithms can use this 120-second window
to save the model artifacts, so the results of training are not lost.
The training algorithms provided by SageMaker automatically save the intermediate results
of a model training job when possible. This attempt to save artifacts is only a best
effort case as model might not be in a state from which it can be saved. For example, if
training has just started, the model might not be ready to save. When saved, this
intermediate data is a valid model artifact. You can use it to create a model with
CreateModel
.
Note
The Neural Topic Model (NTM) currently does not support saving intermediate model artifacts. When training NTMs, make sure that the maximum runtime is sufficient for the training job to complete.
Syntax
To declare this entity in your Amazon CloudFormation template, use the following syntax:
JSON
{ "MaxRuntimeInSeconds" :
Integer
}
YAML
MaxRuntimeInSeconds:
Integer
Properties
MaxRuntimeInSeconds
-
The maximum length of time, in seconds, that a training or compilation job can run before it is stopped.
For compilation jobs, if the job does not complete during this time, a
TimeOut
error is generated. We recommend starting with 900 seconds and increasing as necessary based on your model.For all other jobs, if the job does not complete during this time, SageMaker ends the job. When
RetryStrategy
is specified in the job request,MaxRuntimeInSeconds
specifies the maximum time for all of the attempts in total, not each individual attempt. The default value is 1 day. The maximum value is 28 days.The maximum time that a
TrainingJob
can run in total, including any time spent publishing metrics or archiving and uploading models after it has been stopped, is 30 days.Required: Yes
Type: Integer
Minimum:
1
Maximum:
86400
Update requires: No interruption