Alarm warm-up periods - Amazon CloudWatch
Services or capabilities described in Amazon Web Services documentation might vary by Region. To see the differences applicable to the China Regions, see Getting Started with Amazon Web Services in China (PDF).

Alarm warm-up periods

A warm-up period delays alarm evaluation after you create or update an alarm. This reduces noise from missing data while a new resource or service starts to publish data. During warm-up, the alarm stays in INSUFFICIENT_DATA and does not perform alarm actions.

Use a warm-up period when you deploy alarms with a new application or service that takes time to emit metrics. Without a warm-up period, the alarm can transition and run actions on missing data during startup, and cause false notifications.

Warm-up periods work with metric alarms and log alarms.

Warm-up period configuration

Set the WarmUpConfiguration parameter when you create or update an alarm. This parameter includes the following settings:

  • WarmUpPeriodDurationInMinutes (required) – The warm-up duration, in minutes. Specify a value from 1 to 2,880 minutes (2 days).

  • OnlyStartEvaluatingAfterWarmUpPeriodEnds (optional, default is false) – Controls when evaluation begins. When set to false (default), the alarm ends warm-up early. Evaluation begins as soon as enough data fills its evaluation window. When set to true, the alarm waits the full warm-up duration before it evaluates, even if data arrives sooner. Use this setting when startup fluctuations, such as a CPU spike, could cause premature alarm transitions.

When OnlyStartEvaluatingAfterWarmUpPeriodEnds is false, the alarm ends warm-up as soon as it can fill its evaluation window. The evaluation window spans Period multiplied by Evaluation Periods and is full when a datapoint exists for the most recent period.

For example, an alarm with a 5-minute period and 3 evaluation periods has a 15-minute evaluation window. Suppose that you create this alarm at 10:00 and the resource starts to publish at 10:04. The alarm stays in INSUFFICIENT_DATA until a full 15-minute window is available. This happens at about 10:19, and then the alarm begins to evaluate. The Datapoints to Alarm setting does not affect when warm-up ends.

Change or end a warm-up period

You can change the warm-up configuration while the alarm is still in its warm-up period. You can also end warm-up early when you update the configuration. Warm-up applies only once at alarm creation and does not restart.

After the warm-up period ends, you can update the warm-up configuration. However, the update does not start a new warm-up period. The alarm continues to evaluate normally.

View warm-up status

During warm-up, the alarm state remains INSUFFICIENT_DATA and the evaluation state is IN_WARM_UP. View the alarm configuration and state with the DescribeAlarms API. For more information about evaluation states, see Alarm evaluation state.

For instructions on creating an alarm with a warm-up period, see Create an alarm that uses a warm-up period.