Configure the DescribeDetector API in Amazon IoT Events - Amazon IoT Events
Services or capabilities described in Amazon Web Services documentation might vary by Region. To see the differences applicable to the China Regions, see Getting Started with Amazon Web Services in China (PDF).

End of support notice: On May 20, 2026, Amazon end support for Amazon IoT Events. After May 20, 2026, you will no longer be able to access the Amazon IoT Events console or Amazon IoT Events resources. For more information, visit this Amazon IoT Events end of support.

Configure the DescribeDetector API in Amazon IoT Events

The DescribeDetector API in Amazon IoT Events lets you to retrieve detailed information about a specific detector instance. This operation provides insights into the current state, variable values, and active timers of a detector. By using this API, you can monitor the real-time status of your Amazon IoT Events detectors, facilitating debugging, analysis, and management of your IoT event processing workflows.

CLI command:

aws iotevents-data describe-detector --detector-model-name areaDetectorModel --key-value Area51

Response:

{ "detector": { "lastUpdateTime": 1557521572.216, "creationTime": 1557520274.405, "state": { "variables": [ { "name": "resetMe", "value": "false" }, { "name": "rangeLow", "value": "15.0" }, { "name": "noDelay", "value": "false" }, { "name": "desiredTemperature", "value": "20.0" }, { "name": "anomalousLow", "value": "0.0" }, { "name": "sensorId", "value": "\"01\"" }, { "name": "sensorCount", "value": "10" }, { "name": "rangeHigh", "value": "30.0" }, { "name": "enteringNewState", "value": "false" }, { "name": "averageTemperature", "value": "19.572" }, { "name": "allowedError", "value": "0.7" }, { "name": "anomalousHigh", "value": "60.0" }, { "name": "reportedTemperature", "value": "15.72" }, { "name": "goodToGo", "value": "false" } ], "stateName": "idle", "timers": [ { "timestamp": 1557520454.0, "name": "idleTimer" } ] }, "keyValue": "Area51", "detectorModelName": "areaDetectorModel", "detectorModelVersion": "1" } }