End of support notice: On May 20, 2026, Amazon end support for Amazon IoT Events. After May 20, 2026, you will no longer be able to access the Amazon IoT Events console or Amazon IoT Events resources. For more information, visit this Amazon IoT Events end of support.
Use the Amazon IoT Core rules engine for Amazon IoT Events
The following rules republish Amazon IoT Core MQTT messages as shadow update request messages.
We assume that Amazon IoT Core things are defined for a heating unit and a cooling unit for each
area that is controlled by the detector model. In this example, we have defined things named
"Area51HeatingUnit"
and "Area51CoolingUnit"
.
CLI command:
aws iot create-topic-rule --cli-input-json file://ADMShadowCoolOffRule.json
File: ADMShadowCoolOffRule.json
{ "ruleName": "ADMShadowCoolOff", "topicRulePayload": { "sql": "SELECT topic(3) as state.desired.command FROM 'hvac/Cooling/Off'", "description": "areaDetectorModel mqtt topic publish to cooling unit shadow request", "ruleDisabled": false, "awsIotSqlVersion": "2016-03-23", "actions": [ { "republish": { "topic": "$$aws/things/${payload.detector.keyValue}CoolingUnit/shadow/update", "roleArn": "arn:aws:iam::123456789012:role/service-role/ADMShadowRole" } } ] } }
Response: [empty]
CLI command:
aws iot create-topic-rule --cli-input-json file://ADMShadowCoolOnRule.json
File: ADMShadowCoolOnRule.json
{ "ruleName": "ADMShadowCoolOn", "topicRulePayload": { "sql": "SELECT topic(3) as state.desired.command FROM 'hvac/Cooling/On'", "description": "areaDetectorModel mqtt topic publish to cooling unit shadow request", "ruleDisabled": false, "awsIotSqlVersion": "2016-03-23", "actions": [ { "republish": { "topic": "$$aws/things/${payload.detector.keyValue}CoolingUnit/shadow/update", "roleArn": "arn:aws:iam::123456789012:role/service-role/ADMShadowRole" } } ] } }
Response: [empty]
CLI command:
aws iot create-topic-rule --cli-input-json file://ADMShadowHeatOffRule.json
File: ADMShadowHeatOffRule.json
{ "ruleName": "ADMShadowHeatOff", "topicRulePayload": { "sql": "SELECT topic(3) as state.desired.command FROM 'hvac/Heating/Off'", "description": "areaDetectorModel mqtt topic publish to heating unit shadow request", "ruleDisabled": false, "awsIotSqlVersion": "2016-03-23", "actions": [ { "republish": { "topic": "$$aws/things/${payload.detector.keyValue}HeatingUnit/shadow/update", "roleArn": "arn:aws:iam::123456789012:role/service-role/ADMShadowRole" } } ] } }
Response: [empty]
CLI command:
aws iot create-topic-rule --cli-input-json file://ADMShadowHeatOnRule.json
File: ADMShadowHeatOnRule.json
{ "ruleName": "ADMShadowHeatOn", "topicRulePayload": { "sql": "SELECT topic(3) as state.desired.command FROM 'hvac/Heating/On'", "description": "areaDetectorModel mqtt topic publish to heating unit shadow request", "ruleDisabled": false, "awsIotSqlVersion": "2016-03-23", "actions": [ { "republish": { "topic": "$$aws/things/${payload.detector.keyValue}HeatingUnit/shadow/update", "roleArn": "arn:aws:iam::123456789012:role/service-role/ADMShadowRole" } } ] } }
Response: [empty]