Interface FecOutputSettings.Builder

All Superinterfaces:
Buildable, CopyableBuilder<FecOutputSettings.Builder,FecOutputSettings>, SdkBuilder<FecOutputSettings.Builder,FecOutputSettings>, SdkPojo
Enclosing class:
FecOutputSettings

public static interface FecOutputSettings.Builder extends SdkPojo, CopyableBuilder<FecOutputSettings.Builder,FecOutputSettings>
  • Method Details

    • columnDepth

      FecOutputSettings.Builder columnDepth(Integer columnDepth)
      Parameter D from SMPTE 2022-1. The height of the FEC protection matrix. The number of transport stream packets per column error correction packet. Must be between 4 and 20, inclusive.
      Parameters:
      columnDepth - Parameter D from SMPTE 2022-1. The height of the FEC protection matrix. The number of transport stream packets per column error correction packet. Must be between 4 and 20, inclusive.
      Returns:
      Returns a reference to this object so that method calls can be chained together.
    • includeFec

      FecOutputSettings.Builder includeFec(String includeFec)
      Enables column only or column and row based FEC
      Parameters:
      includeFec - Enables column only or column and row based FEC
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • includeFec

      Enables column only or column and row based FEC
      Parameters:
      includeFec - Enables column only or column and row based FEC
      Returns:
      Returns a reference to this object so that method calls can be chained together.
      See Also:
    • rowLength

      FecOutputSettings.Builder rowLength(Integer rowLength)
      Parameter L from SMPTE 2022-1. The width of the FEC protection matrix. Must be between 1 and 20, inclusive. If only Column FEC is used, then larger values increase robustness. If Row FEC is used, then this is the number of transport stream packets per row error correction packet, and the value must be between 4 and 20, inclusive, if includeFec is columnAndRow. If includeFec is column, this value must be 1 to 20, inclusive.
      Parameters:
      rowLength - Parameter L from SMPTE 2022-1. The width of the FEC protection matrix. Must be between 1 and 20, inclusive. If only Column FEC is used, then larger values increase robustness. If Row FEC is used, then this is the number of transport stream packets per row error correction packet, and the value must be between 4 and 20, inclusive, if includeFec is columnAndRow. If includeFec is column, this value must be 1 to 20, inclusive.
      Returns:
      Returns a reference to this object so that method calls can be chained together.